Quiet, Protected RS-485 / RS-422 Links on a Single 3.3V or 5V Rail

The MxL8311x family pairs slew-rate-limited 250kbps and 500kbps drivers with integrated IEC ESD and EFT protection, so long multidrop cables stay low in emissions and robust against field transients. Both devices operate from 3.0V to 5.5V, allowing the same device family to operate in either 3.3V or 5V systems.

Industrial application with MxL8311x transceiver

Low-Emission RS-485 for Long Cables and 3.3V or 5V Designs

Long RS-485 cables and multidrop networks do not always benefit from fast driver edges. Faster transitions can increase radiated emissions and make reflections from stubs, connectors, or imperfect termination more significant.

MxL8311x devices target cost-sensitive industrial nodes where edge rate and emissions matter more than raw speed. The MxL83111 favors the longest and least ideally terminated cables; the MxL83112 doubles throughput while keeping edges slow enough to tolerate stubs.

Protection, fail-safe, hot-swap and shutdown come standard on both parts, so the same schematic covers sensors, building controllers and command-and-control modules.

Features and Benefits
  • Interoperate on standard networks: electrical characteristics meet or exceed TIA/EIA-485A, over a −7V to +12V common-mode range.
  • Run on 3.3V or 5V: a 3.0V to 5.5V supply keeps working when a nominal 5V rail sags below 4.5V, output exceeds 2.1V differential at 5V for PROFIBUS compatibility.
  • Keep emissions and reflections low: MxL83111 rise/fall times are 350 ns min; MxL83112 are 200 ns min, easing EMC compliance on long or mismatched cables.
  • Provide integrated transient protection: A/B pins are rated for ±8kV IEC 61000-4-2 contact ESD, ±15kV IEC air-gap ESD, ±15kV HBM ESD, and ±2kV IEC 61000-4-4 EFT. The ESD protection is designed to withstand events during normal operation, shutdown, and powered-down states.
  • Grow to 256 nodes: a 96 kΩ, 1/8 unit-load receiver avoids repeaters on large buses.
  • Drop bias resistors: receiver thresholds of −50 mV to −200 mV hold RO high on open, shorted or idle terminated lines with 50 mV margin.
  • Reject slow-edge noise: receiver input filtering plus 30 mV hysteresis keep data clean on heavily loaded lines.
  • Insert cards on a live bus: DE is held low and RE high for about 10 µs at power-up.
  • Save standby power: 1.3mA max supply current and 0.04 µA typical shutdown current extend battery and solar-powered operation.
  • Survive faults: ±250mA short-circuit current limiting and 170 °C thermal shutdown protect against bus contention.
  • Operate at the edge of spec: rated −40 °C to +125 °C and bus pins tolerate −8V to +13V.
MxL8311x chip
Product Specifications

The two devices share the same 8-pin half-duplex architecture, supply range, receiver, network loading, protection, fail-safe, hot-swap, and shutdown features. The primary selection criterion is the required signaling rate and corresponding driver timing.

XLSExport▶
MxL83111 0.25 NSOIC-8 Buy Now - MxL83111 datasheet ±15kV ESD-Protected, 1/8 Load, Failsafe​ RS-485 Transceiver RS-422, RS-485 3.3, 5 1 1 Half 2 15 8 Advanced 256 -8 to 13 - -40 to 125 - - - 1.5 ✔ 0.05 ✔ ✔
MxL83112 0.5 NSOIC-8 Buy Now - MxL83112 datasheet ±15kV ESD-Protected, 1/8 Load, Failsafe​ RS-485 Transceiver RS-422, RS-485 3.3, 5 1 1 Half 2 15 8 Advanced 256 -8 to 13 - -40 to 125 - - - 1.5 ✔ 0.05 ✔ ✔
Applications
Building Automation and HVAC

Long daisy-chained runs to hundreds of thermostats, dampers and access panels, often with imperfect termination.

Instrumentation and Field Sensors

Remote transmitters and data loggers on 3.3V rails where shutdown current sets battery life.

Solar and Battery-Powered Nodes

Irrigation controllers, remote meters and off-grid monitors that sleep between polls.

Industrial Command and Control

PLC I/O, operator panels and fieldbus nodes near relays and contactors.

Industrial Notebooks and Handheld Tools

Portable service equipment that talks to fixed RS-485 installations from a battery supply.

Frequently Asked Questions

MxL83111 for the longest cables and lowest emissions and MxL83112 when you need 500kbps. Both are pin- and package-identical, so the choice can change late in design.

When the system must pass higher IEC levels, sees ground offsets beyond −7V to +12V, needs more than 500kbps, or needs a package smaller than NSOIC-8.

Yes, RS-485-compliant transceivers can share a bus when their electrical requirements are compatible. Account for total receiver loading, termination, common-mode range, and driver characteristics. Each MxL8311x receiver represents 1/8 unit load, allowing up to 256 MxL8311x devices when no other loading reduces the available bus load.

Often for ESD and EFT. Systems that must pass IEC 61000-4-5 surge testing still need external surge protection.

Drive active-low RE high and DE low. The devices are guaranteed not to enter shutdown if this condition lasts less than 50 ns and are guaranteed to enter shutdown when it lasts at least 600 ns. From shutdown, maximum driver enable time is 4.5 µs for MxL83111 and 4.0 µs for MxL83112. Receiver enable time is 4.0 µs maximum for both devices.

Not directly. Logic inputs use TTL thresholds (VIH 2.0V min, VIL 0.8V max). Use a level shifter or the MxL8323x family.

Yes, at both cable ends in the line's characteristic impedance, with short stubs. The slow edges make MxL8311x more forgiving of imperfect termination, not a replacement for it.

RS-485 cable length depends on data rate, cable characteristics, termination and topology. The RS-485/RS-422 standard covers line lengths up to 4,000 ft, while MaxLinear's guidance gives an example of approximately 4,000 ft at 90kbps over 24-AWG twisted pair. Higher data rates require shorter cable lengths. See AN-292 for design guidance.