Build Reliable Serial Connectivity for Demanding Industrial Designs
Build robust RS-485 and RS-422 interfaces with a broad portfolio of low-power, wide-supply, high-performance, and fault-tolerant transceivers.
Protection, Flexibility and Performance for Industrial Networks
RS-485 and RS-422 links often need to operate across long cables, electrically noisy environments, mixed voltage domains, and networks with many connected devices. MaxLinear transceivers are designed to help protect the interface, simplify system design, and support applications ranging from lower-speed industrial links to high-speed backplanes.
MaxLinear offers a broad portfolio of RS-485 and RS-422 transceivers for industrial automation, building automation, infrastructure, embedded systems, and other applications that require reliable differential communication.
Robust
Protection
- Extended ESD and EFT protection
- Bus-fault tolerance up to ±60V
- ±15kV IEC ESD options
Protect against demanding bus conditions on long, noisy cables
Flexible
Supplies
- 3.3V and 5V operation
- Separate VL logic supply
- Logic I/O from 1.65V to 5.5V
Simplify voltage-domain connectivity to processors and MCUs
Reliable
Links
- Advanced receiver fail-safe
- Defined output on open, short and idle bus
- No external bias resistors
Maintain stable communication without external biasing
Speed and
Density
- Data rates up to 80Mbps
- Up to 256 nodes per bus
- 1/8-unit-load devices
Scale speed and network density on a single bus
NEW: MxL8323x
Applications: Industrial Sensors, Industrial automation & Motors, EV charging, Building automation
- Integrated logic level shifter enables RS-485 to connect directly down to 1.8V logic levels
- Supports data rates 500kbps, 20Mbps, and 50Mbps
- High ESD rating ±15kV & EFT rating ±4kV
- Wide common-mode ±15V
- Hot swap capability
- PROFIBUS compatibility
- Supports data rates 250kbps, 500kbps
- ESD (up to ±15kV HBM) & EFT (±2kV) immunity
- Common-mode range: -7V to +12V
- Glitch-free power-up/down hot plug capability
- Industrial sensors
- Building automation
- Supports data rates 250kbps, 500kbps
- ESD (up to ±15kV HBM) & EFT (±2kV) immunity
- Extended common-mode range up to ±12V
- Glitch-free power-up/down hot plug capability
- Industrial sensors
- Building automation
- Supports data rates 250kbps, 500kbps, or 50Mbps
- High EFT (4kV) and ESD (±15kV) immunity
- Extended common-mode range up to ±15V
- Leading low power RS-485, < 300mW
- Industrial Sensors
- Industrial automation & motors
- Building automation
- High speed up to 80Mbps
- High noise and ESD (±15kV) immunity
- Extended common-mode range up to ±15V
- Option global or paired enabled pins
- Motor controller cards
- RS-485 repeaters/re-transmitters
- Multiple encoders or motor drives reporting back to a controller
Find the Right Transceiver for Your Design
Compare MaxLinear RS-485 and RS-422 families by speed, voltage, protection, network size, and package, then move directly to product documentation, samples, and distributor availability.
±60V Fault Tolerant
Survive shorts to 24V/48V rails and miswiring on the bus. ±60V fault tolerance and ±15kV IEC ESD protect the line where field wiring is unpredictable.
Wide-Supply RS-485/RS-422
One part covers 3.0V–5.5V rails and mixed 3.3V/5V systems. Includes 18V-tolerant and quad-receiver options for dense, multi-rail boards.
RS-485/RS-422 (5V Only)
Classic 5V industrial signaling with strong drive and wide common-mode range. Includes PROFIBUS-rated and high-fanout options.
RS-485/RS-422 (3.3V Only)
Low-power 3.3V transceivers, transmitters and receivers for battery- and rail-constrained designs, including tiny TSOT23 half-function parts.
|
MxL83232
New
High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection
Active
|
500kbps High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection | 3.3, 5 | Half | 0.5 | 15 | Advanced | 256 | - | NSOIC-8, MSOP-8 | RS-485, RS-422 | 1 | 1 | 4 | 8 | ✔ | -40 to 125 | - | - | ✔ | - | - | - | - | - | |
|
MxL83233
New
High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection
Active
|
20Mbps High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection | 3.3, 5 | Half | 20 | 15 | Advanced | 256 | - | NSOIC-8, MSOP-8 | RS-485, RS-422 | 1 | 1 | 4 | 8 | ✔ | -40 to 125 | - | - | ✔ | - | - | - | - | - | |
|
MxL83234
New
High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection
Active
|
50Mbps High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection | 3.3, 5 | Half | 50 | 15 | Advanced | 256 | - | NSOIC-8, MSOP-8 | RS-485, RS-422 | 1 | 1 | 4 | 8 | ✔ | -40 to 125 | - | - | ✔ | - | - | - | - | - | |
|
MxL83235
New
High-Performance RS-485/422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection
Active
|
20Mbps High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection | 3.3, 5 | Half | 20 | 15 | Advanced | 256 | - | MSOP-10, DFN-10 | RS-485, RS-422 | 1 | 1 | 4 | 8 | ✔ | -40 to 125 | - | - | ✔ | - | - | - | - | - | |
|
MxL83236
New
High-Performance RS-485/422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection
Active
|
50Mbps High-Performance RS-485 / 422 Transceivers with 1.65V-5.5V I/O Interface and Extended IEC ESD and EFT Protection | 3.3, 5 | Half | 50 | 15 | Advanced | 256 | - | MSOP-10, DFN-10 | RS-485, RS-422 | 1 | 1 | 4 | 8 | ✔ | -40 to 125 | - | - | ✔ | - | - | - | - | - | |
|
MxL83101
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver
Active
|
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver | 5 | Half | 0.25 | 15 | Advanced | 256 | -8 to 13 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | 2 | 8 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.05 | ✔ | ✔ | |
|
MxL83102
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver
Active
|
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver | 5 | Half | 0.5 | 15 | Advanced | 256 | -8 to 13 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | 2 | 8 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.05 | ✔ | ✔ | |
|
MxL83111
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver
Active
|
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver | 3.3, 5 | Half | 0.25 | 15 | Advanced | 256 | -8 to 13 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | 2 | 8 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.05 | ✔ | ✔ | |
|
MxL83112
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver
Active
|
±15kV ESD-Protected, 1/8 Load, Failsafe RS-485 Transceiver | 3.3, 5 | Half | 0.5 | 15 | Advanced | 256 | -8 to 13 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | 2 | 8 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.05 | ✔ | ✔ | |
|
MxL83121
RS-485 Transceiver with Extended IEC ESD and EFT Protection
Active
|
RS-485 Transceiver with Extended IEC ESD and EFT Protection | 3.3, 5 | Half | 0.25 | 15 | Advanced | 256 | -15 to 15 | NSOIC-8 | RS-485, RS-422 | 1 | 1 | 2 | 12 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.1 | ✔ | ✔ | |
|
MxL83122
RS-485 Transceiver with Extended IEC ESD and EFT Protection
Active
|
RS-485 Transceiver with Extended IEC ESD and EFT Protection | 3.3, 5 | Half | 0.5 | 15 | Advanced | 256 | -15 to 15 | NSOIC-8 | RS-485, RS-422 | 1 | 1 | 2 | 12 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.1 | ✔ | ✔ | |
|
MxL83211
High Performance RS-485 Transceiver with Extended IEC ESD and EFT
Active
|
High Performance RS-485 Transceiver with Extended IEC ESD and EFT | 3.3, 5 | Half | 0.25 | 15 | Advanced | 256 | - | NSOIC8 | RS-422, RS-485 | 1 | 1 | 4 | 12 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.1 | ✔ | ✔ | |
|
MxL83212
High Performance RS-485 Transceiver with Extended IEC ESD and EFT
Active
|
High Performance RS-485 Transceiver with Extended IEC ESD and EFT | 3.3, 5 | Half | 0.5 | 15 | Advanced | 256 | - | NSOIC-8, MSOP-8, VSON-8 | RS-422, RS-485 | 1 | 1 | 4 | 12 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.1 | ✔ | ✔ | |
|
MxL83214
High Performance RS-485 Transceiver with Extended IEC ESD and EFT
Active
|
High Performance RS-485 Transceiver with Extended IEC ESD and EFT | 3.3, 5 | Half | 50 | 15 | Advanced | 256 | - | NSOIC-8, MSOP-8, VSON-8 | RS-422, RS-485 | 1 | 1 | 4 | 12 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.1 | ✔ | ✔ | |
|
MxL83411
Quad RS-485 Receiver with IEC, ESD and EFT and Global Enable
Active
|
Quad RS-485 Receiver with IEC, ESD and EFT and Global Enable | 3.3, 5 | - | 10 | 15 | Standard | 128 | - | NSOIC-16, TSSOP-16 | RS-422, RS-485 | 0 | 4 | 2 | 8 | - | -40 to 85; -40 to 125 | - | - | - | 4 | - | - | ✔ | - | |
|
MxL83433
32Mbps Quad RS-485 Receiver with High IEC ESD/EFT and Global Enable
Active
|
32Mbps Quad RS-485 Receiver with High IEC ESD and EFT and Global Enable | 3.3, 5 | - | 32 | 15 | Standard | 128 | - | NSOIC-16, TSSOP-16 | RS-485, RS-422 | 0 | 4 | 4 | 12 | - | -40 to 85, -40 to 125 | - | - | Global | 7 | - | - | ✔ | - | |
|
MxL83434
32Mbps Quad RS-485 Receiver with High IEC ESD/EFT and Paired Enable
Active
|
32Mbps Quad RS-485 Receiver with High IEC ESD and EFT and Paired Enable | 3.3, 5 | - | 32 | 15 | Standard | 128 | - | NSOIC-16, TSSOP-16 | RS-485, RS-422 | 0 | 4 | 4 | 12 | - | -40 to 85, -40 to 125 | - | - | Paired | 7 | - | - | ✔ | - | |
|
MxL83435
65Mbps Quad RS-485/422 Receiver with High IEC ESD/EFT and Global Enable
Active
|
65Mbps Quad RS-485/422 Receiver with High IEC ESD and EFT and Global Enable | 3.3, 5 | - | 65 | 15 | Standard | 128 | - | NSOIC-16, TSSOP-15 | RS-485, RS-422 | 0 | 4 | 4 | 12 | - | -40 to 125 | - | - | Global | 7 | - | - | ✔ | - | |
|
MxL83436
65Mbps Quad RS-485/422 Receiver with High IEC ESD/EFT and Paired Enable
Active
|
65Mbps Quad RS-485/422 Receiver with High IEC ESD and EFT and Paired Enable | 3.3, 5 | - | 65 | 15 | Standard | 128 | - | NSOIC-16, TSSOP-15 | RS-485, RS-422 | 0 | 4 | 4 | 12 | - | -40 to 125 | - | - | Global | 7 | - | - | ✔ | - | |
|
MxL83437
80Mbps Quad RS-485/422 Receiver with High IEC ESD/EFT and Global Enable
Active
|
80Mbps Quad RS-485/422 Receiver with High IEC ESD and EFT and Global Enable | 5 | - | 80 | 15 | Standard | 128 | - | NSOIC-16, TSSOP-16 | RS-485, RS-422 | 0 | 4 | 4 | 12 | - | –40°C to 125°C | - | - | Global | 7 | - | - | ✔ | - | |
|
MxL83438
80Mbps Quad RS-485/422 Receiver with High IEC ESD/EFT and Paired Enable
Active
|
80Mbps Quad RS-485/422 Receiver with High IEC ESD and EFT and Paired Enable | 5 | - | 80 | 15 | Standard | 128 | - | NSOIC-16, TSSOP-16 | RS-485, RS-422 | 0 | 4 | 4 | 12 | - | –40°C to 125°C | - | - | Paired | 7 | - | - | ✔ | - | |
|
SP1485E
20Mbps Half-Duplex RS-485 Transceivers with +/-15KV ESD
Active
|
20Mbps Half-Duplex RS-485 Transceivers with +/-15KV ESD | 5 | Half | 20 | 15 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | MxL83214 | - | - | - | - | - | - | - | |
|
SP1486E
5V, 15kV ESD, PROFIBUS RS-485 Half-Duplex Transceiver
Active
|
5V, 15kV ESD, PROFIBUS RS-485 Half-Duplex Transceiver | 5 | Half | 20 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83214 | - | - | 1 | - | 1 | - | ✔ | |
|
SP3070E
3.3V, 15kV, Failsafe RS-485 Full-Duplex with Slew Limit
Active
|
3.3V, 15kV, Failsafe RS-485 Full-Duplex with Slew Limit | 3.3 | Full | 0.25 | 15 | Advanced | 256 | - | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | - | - | 1.5 | ✔ | 0.05 | ✔ | - | |
|
SP3071E
3.3V, 15kV, Failsafe RS-485 Full-Duplex with Slew Limit
Active
|
3.3V, 15kV, Failsafe RS-485 Full-Duplex with Slew Limit | 3.3 | Full | 0.25 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | - | - | 1.5 | - | 0.05 | - | - | |
|
SP3072E
3.3V, 15kV, Failsafe RS-485 Half-Duplex with Slew Limit
Active
|
3.3V, 15kV, Failsafe RS-485 Half-Duplex with Slew Limit | 3.3 | Half | 0.25 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85,-40 to 125 | MxL83111, MxL83121, MxL83211 | - | - | 1.5 | ✔ | 0.5 | ✔ | - | |
|
SP3073E
|
3.3V, 15kV, Failsafe RS-485 Full-Duplex | 3.3 | Full | 0.5 | 15 | Advanced | 256 | - | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | - | - | 1.5 | ✔ | 0.5 | ✔ | - | |
SP3074E
|
3.3V, 15kV, Failsafe RS-485 Full-Duplex | 3.3 | Full | 0.5 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | - | - | 1.5 | - | 0.05 | - | - | |
SP3075E
|
3.3V, 15kV, Failsafe RS-485 Half-Duplex | 3.3 | Half | 0.5 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83122, MxL83212, MxL83112 | - | - | 1.5 | ✔ | 0.5 | ✔ | - | |
|
SP3076E
High Speed, 3.3V, 15kV, Failsafe RS-485 Full-Duplex
Active
|
High Speed, 3.3V, 15kV, Failsafe RS-485 Full-Duplex | 3.3 | Full | 16 | 15 | Advanced | 256 | - | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85,-40 to 125 | - | - | - | 1.5 | ✔ | 0.5 | ✔ | - | |
|
SP3077E
High Speed, 3.3V, 15kV, Failsafe RS-485 Full-Duplex
Active
|
High Speed, 3.3V, 15kV, Failsafe RS-485 Full-Duplex | 3.3 | Full | 16 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | - | - | 1.5 | - | 0.05 | - | - | |
|
SP3078E
High Speed, 3.3V, 15kV, Failsafe RS-485 Half-Duplex
Active
|
High Speed, 3.3V, 15kV, Failsafe RS-485 Half-Duplex | 3.3 | Half | 16 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85,-40 to 125 | MxL83214 | - | - | 1.5 | ✔ | 0.5 | ✔ | - | |
|
SP3082E
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected
Active
|
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected | 5 | Half | 0.115 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83101, MxL83121, MxL83211 | -65 to 65 | - | 0.9 | ✔ | 1 | ✔ | - | |
|
SP3083E
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected
Active
|
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected | 5 | Full | 0.5 | 15 | Advanced | 256 | - | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | -65 to 65 | - | 0.9 | ✔ | 1 | ✔ | - | |
|
SP3085E
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected
Active
|
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected | 5 | Half | 0.5 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83122, MxL83212, MxL83102, MxL83112 | -65 to 65 | - | 0.9 | ✔ | 1 | ✔ | - | |
|
SP3088E
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected
Active
|
Advanced Failsafe RS-485 Transceivers 1/8th Unit Load, Slew-Rate Limited, ±15kV ESD-Protected | 5 | Half | 20 | 15 | Advanced | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83214 | -65 to 65 | - | 0.9 | ✔ | 1 | ✔ | - | |
|
SP3483
3.3V Low Power Slew Rate Limited Half-Duplex RS-485 Transceiver
Active
|
3.3V Low Power Slew Rate Limited Half-Duplex RS-485 Transceiver | 3.3 | Half | 0.25 | 2 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | MxL83111, MxL83121, MxL83211 | - | - | 2 | ✔ | 1 | - | - | |
|
SP3485
3.3V Low Power Half-Duplex RS-485 Transceivers with 10Mbps Data Rate
Active
|
3.3V Low Power Half-Duplex RS-485 Transceivers with 10Mbps Data Rate | 3.3 | Half | 10 | 2 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | MxL83214 | - | - | 2 | - | 10 | - | - | |
|
SP3490
3.3V Low Power Full Duplex RS-485 Transceivers with 10Mbps Data Rate
Active
|
3.3V Low Power Full Duplex RS-485 Transceivers with 10Mbps Data Rate | 3.3 | Full | 10 | 2 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | - | - | - | 2 | - | - | - | - | |
SP3494
|
3.3V Slew Limited RS-485, 2.5Mbps Half-Duplex | 3.3 | Half | 2.5 | 2 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | - | - | - | 2 | ✔ | 10 | - | - | |
SP4082E
|
5V RS-485/RS-422 Half-Duplex Transceiver | 5 | Half | 0.115 | 15 | Standard | 256 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85 | MxL83101, MxL83121, MxL83211 | - | - | 0.9 | - | 400 | - | - | |
SP481E
|
Enhanced Low Power Half-Duplex RS-485 Transceivers | 5 | Half | 10 | 15 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | 0 to 70, -40 to 85 | MxL83214 | - | - | - | ✔ | 1 | - | - | |
SP483
|
Low Power Half-Duplex RS-485 Transceivers | 5 | Half | 0.25 | 2 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 2 | - | 0 to 70, -40 to 85 | MxL83101, MxL83121, MxL83211 | - | - | - | ✔ | 1 | - | - | |
SP483E
|
Enhanced Low EMI Half-Duplex RS-485 Transceiver | 5 | Half | 0.25 | 15 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | 0 to 70, -40 to 85 | MxL83101, MxL83121, MxL83211 | - | - | - | ✔ | 1 | - | - | |
SP485
|
Low Power Half-Duplex RS-485 Transceivers | 5 | Half | 5 | 2 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 2 | - | 0 to 70, -40 to 85 | MxL83214 | - | - | - | - | - | - | - | |
SP485E
|
Enhanced Low EMI Half-Duplex RS-485 Transceiver | 5 | Half | 10 | 15 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | 0 to 70, -40 to 85,-40 to 125 | MxL83214 | - | - | - | - | - | - | - | |
SP485R
|
High-Fanout RS-485 Transceiver | 5 | Half | 5 | 2 | Standard | 400 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | - | - | - | 0.5 | - | 0.5 | - | - | |
SP490
|
Full Duplex RS-485 Transceivers | 5 | Full | 5 | 2 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | - | - | - | - | - | - | - | - | |
SP490E
|
Enhanced Full Duplex RS-485 Transceivers | 5 | Full | 10 | 15 | Standard | 32 | - | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | - | - | - | - | - | - | - | - | |
SP491
|
Full Duplex RS-485 Transceivers | 5 | Full | 5 | 2 | Standard | 32 | - | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | - | - | - | - | ✔ | - | - | - | |
SP491E
|
Enhanced Full Duplex RS-485 Transceivers | 5 | Full | 10 | 15 | Standard | 32 | - | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | - | - | 0 to 70, -40 to 85 | - | - | - | - | ✔ | - | - | - | |
|
XR3072X
Low Power 18V Tolerant RS-485/RS-422 +3.3V Transceivers
Active
|
Low Power 18V Tolerant RS-485/RS-422 +3.3V Transceivers | 3.3 | Half | 0.25 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83211 | -70 to 70 | - | 0.6 | ✔ | 1nA | ✔ | ✔ | |
|
XR3078X
Low Power 18V Tolerant RS-485/RS-422 +3.3V Transceivers
Active
|
Low Power 18V Tolerant RS-485/RS-422 +3.3V Transceivers | 3.3 | Half | 20 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83214 | -70 to 70 | - | 0.6 | ✔ | 1nA | ✔ | ✔ | |
|
XR3082X
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers
Active
|
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers | 5 | Half | 0.25 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83211 | -70 to 70 | - | 0.6 | ✔ | 1nA | ✔ | ✔ | |
|
XR3085X
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers
Active
|
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers | 5 | Half | 1 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | -70 to 70 | - | 0.6 | ✔ | 1nA | ✔ | ✔ | |
|
XR3087X
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers
Active
|
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers | 5 | Full | 20 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | -70 to 70 | - | 0.6 | ✔ | 1nA | - | ✔ | |
|
XR3088X
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers
Active
|
High Output 18V Tolerant RS-485/RS-422 +5V Transceivers | 5 | Half | 20 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83214 | -70 to 70 | - | 0.6 | ✔ | 1nA | ✔ | ✔ | |
|
XR33032
Wide Supply 18V Tolerant RS-485/RS-422 Transceivers
Active
|
Wide Supply 18V Tolerant RS-485/RS-422 Transceivers | 3.3, 5 | Half | 0.25 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83211 | -70 to 70 | - | 0.6 | ✔ | 0.04 | ✔ | - | |
|
XR33035
Wide Supply 18V Tolerant RS-485/RS-422 Transceivers
Active
|
Wide Supply 18V Tolerant RS-485/RS-422 Transceivers | 3.3, 5 | Half | 1 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | - | -70 to 70 | - | 0.6 | ✔ | 0.04 | ✔ | - | |
|
XR33038
Wide Supply 18V Tolerant RS-485/RS-422 Transceivers
Active
|
Wide Supply 18V Tolerant RS-485/RS-422 Transceivers | 3.3, 5 | Half | 10 | 15 | Advanced | 256 | -18 to 18 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | 8 | - | -40 to 85 | MxL83214 | -70 to 70 | - | 0.6 | ✔ | 0.04 | ✔ | - | |
|
XR33052
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver
Active
|
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver | 3.3, 5 | Half | 0.25 | 15 | Advanced | 320 | -60 to 60 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | ✔ | 0.001 | ✔ | - | |
XR33053
|
±60V Fault Tolerant 3.0V to 5.5V TIA-485/TIA-422 1Mbps Full Duplex Transceiver | 3.3, 5 | Full | 1 | 15 | Advanced | 320 | -60 to 60 | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | ✔ | 0.001 | ✔ | - | |
|
XR33055
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver
Active
|
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver | 3.3, 5 | Half | 1 | 15 | Advanced | 320 | -60 to 60 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | ✔ | 0.001 | ✔ | - | |
|
XR33058
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver
Active
|
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver | 3.3, 5 | Half | 20 | 15 | Advanced | 80 | -60 to 60 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | ✔ | 0.001 | ✔ | - | |
|
XR33152
±60V Fault Tolerant 3.0V to 5.5V TIA-485/TIA-422 Transceiver
Active
|
±60V Fault Tolerant 3.0V to 5.5V TIA-485/TIA-422 250Kbps Half Duplex Transceiver | 3.3, 5 | Half | 0.25 | 15 | Advanced | 320 | -60 to 60 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | - | - | ✔ | - | |
|
XR33155
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver
Active
|
±60V Fault Tolerant 3.0V to 5.5V RS-485/RS-422 Transceiver | 3.3, 5 | Half | 1 | 15 | Advanced | 320 | -60 to 60 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | - | - | - | - | |
|
XR33156
±60V Fault Tolerant 3.0V to 5.5V TIA-485/TIA-422 Transceiver
Active
|
±60V Fault Tolerant 3.0V to 5.5V TIA-485/TIA-422 20Mbps Full Duplex Transceiver with VL Pin | 3.3, 5 | Full | 20 | 15 | Advanced | 80 | -60 to 60 | NSOIC-14 | RS-422, RS-485 | 1 | 1 | - | - | ✔ | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | ✔ | 0.001 | ✔ | - | |
|
XR33158
±60V Fault Tolerant 3.0V to 5.5V TIA-485/TIA-422 Transceiver
Active
|
±60V Fault Tolerant 3.0V to 5.5V TIA-485/TIA-422 20Mbps Half Duplex Transceiver | 3.3, 5 | Half | 20 | 15 | Advanced | 80 | -60 to 60 | NSOIC-8 | RS-422, RS-485 | 1 | 1 | - | - | - | -40 to 85, -40 to 105 | - | -100 to 100 | - | 4 | - | - | ✔ | - | |
|
XR33180
3V to 5.5V, 52Mbps, TSOT23 RS-485/RS-422 Receiver with ±15kV ESD Protection
Active
|
3V to 5.5V, 52Mbps, TSOT23 RS-485/RS-422 Receiver with ±15kV ESD Protection | 3.3, 5 | - | 52 | 15 | Advanced | 128 | - | TSOT23-5 | RS-422, RS-485 | 0 | 1 | - | 8 | - | -40 to 125 | - | - | - | 5 | - | - | - | - | |
|
XR33181
3V to 5.5V, 52Mbps, TSOT23 RS-485/RS-422 Receiver with ±15kV ESD Protection
Active
|
3V to 5.5V, 52Mbps, TSOT23 RS-485/RS-422 Receiver with ±15kV ESD Protection | 3.3, 5 | - | 52 | 15 | Advanced | 128 | - | TSOT23-6 | RS-422, RS-485 | 0 | 1 | - | 8 | - | -40 to 125 | - | - | - | 5 | - | - | - | - | |
|
XR33183
3V to 5.5V, 52Mbps, TSOT23 RS-485/RS-422 Receiver with ±15kV ESD Protection
Active
|
3V to 5.5V, 52Mbps, TSOT23 RS-485/RS-422 Receiver with ±15kV ESD Protection | 3.3, 5 | - | 52 | 15 | Advanced | 128 | - | TSOT23-6 | RS-422, RS-485 | 0 | 1 | - | 8 | - | -40 to 125 | - | - | - | 5 | - | - | - | - | |
|
XR33193
3.3V, 250kbps, TSOT23 RS-485/RS-422 Transmitter with ±15kV ESD Protection
Active
|
3.3V, 20Mbps, TSOT23 RS-485/RS-422 Transmitter with ±15kV ESD Protection | 3.3 | - | 0.25 | 15 | - | - | - | TSOT23-6 | RS-422, RS-485 | 1 | 0 | - | 8 | - | -40 to 125 | - | - | - | 0.375 | ✔ | 2 | ✔ | - | |
|
XR33194
3.3V, 2.5Mbps, TSOT23 RS-485/RS-422 Transmitter with ±15kV ESD Protection
Active
|
3.3V, 20Mbps, TSOT23 RS-485/RS-422 Transmitter with ±15kV ESD Protection | 3.3 | - | 2.5 | 15 | - | - | - | TSOT23-6 | RS-422, RS-485 | 1 | 0 | - | 8 | - | -40 to 125 | - | - | - | 0.375 | ✔ | 2 | ✔ | - | |
|
XR33195
3.3V, 20Mbps, TSOT23 RS-485/RS-422 Transmitter with ±15kV ESD Protection
Active
|
3.3V, 20Mbps, TSOT23 RS-485/RS-422 Transmitter with ±15kV ESD Protection | 3.3 | - | 20 | 15 | - | - | - | TSOT23-6 | RS-422, RS-485 | 1 | 0 | - | 8 | - | -40 to 125 | - | - | - | 0.375 | ✔ | 2 | ✔ | - | |
|
XR33202
Wide Supply TIA-485/TIA-422 Transceiver with 1.65V-5.5V I/O Interface
Active
|
Wide Supply TIA-485/TIA-422 Transceiver with 1.65V-5.5V I/O Interface | 3.3, 5 | Half | 20 | 15 | Advanced | >256 | - | DFN-10 | RS-422, RS-485 | 1 | 1 | - | 8 | ✔ | -40 to 125 | MxL83233, MxL83234, MxL83235, MxL83236 | - | - | 0.6 | ✔ | 0.05 | ✔ | - |
No products match the selected filters.
RS-485/RS-422 Application Notes
An RS-485 transceiver is an interface device that converts logic-level signals from a processor or microcontroller into differential signals for transmission over an RS-485 bus, and converts received differential signals back into logic levels. RS-485 supports multipoint communication, allowing multiple nodes to share the same bus. It is widely used where long cable runs, electrical noise, and reliable communication between multiple devices are important.
RS-422 is a differential serial communication standard designed for reliable data transmission over longer distances and in electrically noisy environments. It typically uses one driver communicating with one or more receivers and is commonly implemented as a point-to-point or point-to-multipoint connection.
RS-232, RS-422, and RS-485 are serial communication standards designed for different connection requirements. RS-232 uses single-ended signaling and is typically used for short-distance, point-to-point communication between two devices. RS-422 uses differential signaling for better noise immunity and longer cable distances, typically with one driver and multiple receivers. RS-485 also uses differential signaling but supports multipoint networks, allowing multiple transmitters and receivers to share the same bus. RS-485 is commonly selected for industrial networks that require longer distances, higher noise immunity, and multiple connected nodes.
On a factory floor the A/B pair can be miswired, shorted to a 24V or 48V rail, or hit by a ground-potential difference between nodes. A ±60V fault-tolerant transceiver such as the XR33052/XR33055/XR33155 keeps its bus pins from being destroyed under those conditions, so a wiring mistake during install does not kill the board. Standard RS-485 parts only guarantee roughly −7V to +12V common-mode range.
The RS-485 standard defines 32 unit loads. Transceivers that present a fractional unit load put more receivers on the same bus before the drivers run out of margin. MaxLinear 1/8-unit-load parts (for example the MxL8311x family) allow up to 256 nodes on a single segment; see the Nodes column in the category tables for each part.
The Vₗ pin gives the logic/host side its own supply, independent of the bus-side Vᴄᴄ. You can run the RS-485 bus at 3.3V or 5V while the digital pins interface directly with a 1.65V–5.5V microcontroller without the need for a discrete level shifter. It eliminates one component and saves board area. It is the headline feature of the MxL83232–MxL83236 family.
Many are pin- and function-compatible upgrades for legacy Sipex (SP-prefix) and Exar (XR-prefix) devices. Upgrades typically add higher IEC ESD/EFT ratings, better fail-safe behavior and wider data-rate range. Confirm pinout and package against the target datasheet before committing.
MaxLinear offers alternatives to selected RS-485 and RS-422 devices from Texas Instruments, Analog Devices, Renesas, 3PEAK, and other suppliers. Depending on the device, MaxLinear options can provide comparable functionality with differences in protection, data rate, supply range, node count, logic-interface support, and package options. Use the Cross-Reference Guide to identify potential replacements and compare the specifications required for the design.
Fail-safe biasing forces the receiver output to a known logic HIGH when the bus is idle, open, or shorted, instead of chattering on noise. Parts marked “Advanced” fail-safe hold a defined state across open, short and idle-bus conditions without external bias resistors, which simplifies the design and improves reliability.
PROFIBUS-DP needs a 5V transceiver with the right drive and timing. The SP1486E is a 5V, 15kV-ESD, PROFIBUS-rated RS-485 half-duplex transceiver in the 5V-only category; for a modern high-performance upgrade look at the MxL8321x/MxL8323x parts.
RS-485 trades data rate against cable length: long buses (up to ~1200 m) run at lower rates, short links run faster. Pick the lowest data-rate part that meets your throughput — slew-rate-limited devices (for example SP3483, SP3494) reduce reflections and EMI on long or unterminated cable, while parts up to 50–80Mbps (MxL83234, MxL83437/38) suit short, controlled-impedance backplanes.
Every part links to a live DigiKey and Mouser stock-and-price search for that exact part number on the web page. Use them to confirm distributor inventory in your region before designing a part in. For samples and full datasheets, follow the part-number link to maxlinear.com.
Several do. Hot-swap circuitry prevents false transitions on the bus while a board is inserted into a live backplane, and a low-current shutdown mode drops the device to microamp-level supply current when idle. The XR330xx/XR331xx and XR307xX families list hot-swap and shutdown support; check the individual datasheet for exact behavior.