Extended Common-Mode and Integrated IEC Protection for 250/500kbps RS-485 Links
The MxL8312x family combines slew-rate-limited 250kbps and 500kbps operation with a −12V to +12V operational common-mode range, integrated IEC ESD and EFT protection, and a 3.0V to 5.5V supply. A 1/8-unit-load receiver supports up to 256 transceivers on a half-duplex bus.
Wider Common-Mode Margin for Nodes That Do Not Share a Clean Ground
TIA/EIA-485A specifies receiver operation from −7V to +12V. Motor drives, grid equipment and nodes in separate cabinets or buildings can see ground differences that push the bus toward or past those limits.
MxL8312x extends the operating common-mode range to ±12V, and the bus pins withstand ±15V absolute maximum. The MxL83121 runs at 250kbps with the slowest driver edges in the family. The MxL83122 doubles the rate to 500kbps.
Both parts use the same NSOIC-8 pinout and share every receiver, protection and power specification, so one layout supports either speed grade.
- Operate across larger ground offsets: the extended common-mode range keeps driver and receiver within specification when node grounds differ.
- Use one family for 3.3V and 5V rails: the devices operate from 3.0V to 5.5V. With VCC from 4.5V to 5.5V, differential output is specified at 2.1V minimum across the extended common-mode range for PROFIBUS compatibility.
- Provide integrated bus protection: A and B are rated for ±12kV IEC 61000-4-2 contact ESD, ±15kV IEC air-gap ESD, ±15kV HBM ESD, and ±2kV IEC 61000-4-4 EFT.
- Connect up to 256 nodes: the receiver presents a 96 kΩ, 1/8-unit load. A bus can support up to 256 MxL8312x transceivers when the total receiver loading remains within 32 standard unit loads.
- Limit EMI and cable reflections: MxL83121 uses slew-rate-limited drivers for 250kbps operation. MxL83122 increases the allowable slew rate for 500kbps operation while retaining controlled edges.
- Maintain a defined receiver state: enhanced fail-safe circuitry drives RO high when the bus is open, shorted, or idle with all transmitters disabled.
- Filter slow-edge noise: receiver input filtering works with 30 mV typical hysteresis to improve noise immunity when differential signals have slow rise and fall times.
- Support live insertion: during power-up, internal circuitry holds DE low and active-low RE high for approximately 10 µs to prevent unintended bus activity while the controlling processor initializes.
- Reduce standby current: shutdown current is specified at 0.1 µA typical and 1.2 µA maximum when active-low RE is high and DE is low.
- Protect against driver faults: driver short-circuit current is limited to ±250mA, and thermal shutdown activates at approximately 170 °C. The devices are specified for −40 °C to +125 °C ambient operation.
Driver timing sets the choice between the two parts. Values apply over −40 °C to +125 °C and VCC = 3.0V to 5.5V.
|
MxL83121
RS-485 Transceiver with Extended IEC ESD and EFT Protection
Active
|
0.25 | NSOIC-8 | Buy Now | - | MxL83121 datasheet | RS-485 Transceiver with Extended IEC ESD and EFT Protection | RS-485, RS-422 | 3.3, 5 | 1 | 1 | Half | 2 | 15 | 12 | Advanced | 256 | -15 to 15 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.1 | ✔ | ✔ | |
|
MxL83122
RS-485 Transceiver with Extended IEC ESD and EFT Protection
Active
|
0.5 | NSOIC-8 | Buy Now | - | MxL83122 datasheet | RS-485 Transceiver with Extended IEC ESD and EFT Protection | RS-485, RS-422 | 3.3, 5 | 1 | 1 | Half | 2 | 15 | 12 | Advanced | 256 | -15 to 15 | - | -40 to 125 | - | - | - | 1.5 | ✔ | 0.1 | ✔ | ✔ |
No products match the selected filters.
Motor Drives
- Recommended:
MxL83122
Command and status links routed near inverter outputs, where switching noise and ground shift between drive and controller are common.
Smart Grid Equipment
- Recommended:
MxL83121
Meters, data concentrators and substation monitors connected over long runs between separately grounded enclosures.
Industrial and Process Control
- Recommended:
MxL83122
PLC I/O, remote I/O and fieldbus nodes mounted beside relays and contactors that generate fast transients.
Industrial and Single-Board Computers
- Recommended:
MxL83122
On-board RS-485 ports where one transceiver must serve both 3.3V and 5V board designs.
Relevant Resources
MxL8312x widens the operating common-mode range to ±12V (MxL8311x: −7V to +12V), raises IEC 61000-4-2 contact ESD to ±12kV (MxL8311x: ±8kV) and tolerates ±15V on the bus pins (MxL8311x: −8V to +13V). Speed grades, supply range and package are the same.
Choose MxL8321x for ±4kV EFT, a ±15V common-mode range, data rates up to 50Mbps (MxL83214), or MSOP-8 and VSON-8 packages.
The receiver operates with −12V to +12V common mode at its pins. That budget includes the driver common-mode output, up to 3V, plus any ground difference between nodes. The Signaling Common Mode Voltage Operating Range application note covers the calculation.
The total must stay at or below 32 unit loads. Each MxL8312x is 1/8 unit load, so a bus with eight 1-unit-load transceivers still has room for 192 MxL8312x nodes.
The integrated protection covers ESD and EFT to the specified IEC levels. The MxL8312x data sheet does not specify IEC 61000-4-5 surge immunity. Systems subject to surge requirements may require additional external protection based on the required system-level test conditions.
Drive RE high and DE low. The device will not enter shutdown if this state lasts less than 50 ns and is guaranteed to enter it after 600 ns. Driver and receiver enable times from shutdown are 14 µs maximum on both parts.
No. DI, DE and RE require 2.0V minimum for a logic high, so a 1.8V controller needs a level translator.
Yes. Terminate both cable ends in the line's characteristic impedance and keep stubs short. The slow edges make the devices more tolerant of imperfect termination, not independent of it. See AN-292 for cable length versus data rate.